![]() ![]() I also have doubts regarding dev_config.dt. The Siemens PLC is IO Controler and there is no GSDML file! In addition to export GSDML file from TIA Portal, Siemens PLC must be configured as I-Device, but it is not possible, because for that you need to specify another IO Controller. I made the configuration but in documentation is written that GSDML file for Siemens PLC must be imported. fdcml file, which can be obtained from FANUC file. Now I am straggling with creation of tic.zip and dev_config.dt.įor tic.zip you need PLCnext Engineer 2022 software from PHOENIX CONTCT to create file. ![]() The creation of device1.zip (device1.xml) is clear. I connect PROFINET FANUC board to the switch at port 3.Īccording the manual three files must be created: device1.zip, tic.zip, dev_config.dt By means of TIA Portal I set IP address and PROBINET name to the PROFINET FANUC board. I insert PROFINET Stack into Device & Network, and add DI 512 and DO 512 at slot 1 and 2 respectively. The FANUC communication card is PROFINET FANUC board (A05B-2600-S523). ![]() I must to make PROFINET IO communication between Siemens S7 1512SP PLC with FANUC Robor R-30iB Plus. ![]()
0 Comments